Why size matters
Every pump start heats the motor. A tank that is too small makes the pump start too often, which shortens its life. The goal is at least one minute of pump run time per start, and two is better.
Drawdown vs. tank size
A tank's labeled size (for example 44 gallons) is not the water it delivers. Drawdown depends on the pressure setting. At 40/60 PSI, a typical tank delivers roughly a quarter to a third of its labeled volume.
| Pump flow | Minimum drawdown | Typical tank (40/60) |
|---|---|---|
| 5 GPM | 5 gal | 20 – 32 gal |
| 7 GPM | 7 gal | 32 – 44 gal |
| 10 GPM | 10 gal | 44 – 62 gal |
| 15 GPM | 15 gal | 80 – 86 gal |
Setting the air charge
With the tank empty, set the air charge 2 PSI below cut-in. For a 40/60 switch that is 38 PSI. Recheck once or twice a year.
Constant pressure systems